§ SR-10. Final plat requirements.  


Latest version.
  • The final plat shall be prepared by a licensed professional engineer or land surveyor and shall provide the information noted in this section and all other requirements set forth in § 335 of the New York State Real Property Law:
    A. 
    The drawing sheet:
    (1) 
    Size: 20 inches by 36 inches.
    (2) 
    Scale: one inch equals 100 feet or larger.
    (3) 
    If more than one sheet is required, a clearly drawn match line shall be shown on both sheets and on the key map.
    B. 
    Key map of the entire subdivision, which shall be the same as that required on the preliminary layout with the following additions:
    (1) 
    The final plat area being submitted for approval shall be shaded if it is only one section of the entire subdivision.
    C. 
    Boundary lines:
    (1) 
    Building zone districts.
    (2) 
    Special districts.
    (3) 
    Municipal areas.
    D. 
    General information required:
    (1) 
    Street rights-of-way and widening of street rights-of-way:
    (a) 
    Name.
    (b) 
    Location.
    (c) 
    Width.
    (d) 
    Notation on widenings where an offer of dedication is being made.
    (2) 
    Other rights-of-way and easements.
    (a) 
    Identification and description.
    (b) 
    Location.
    (c) 
    Width and other dimensions necessary for description.
    (3) 
    Lot layout:
    (a) 
    Number identification by a suitable system of consecutive numbers; numbers shall be circled or underlined.
    (b) 
    Lot lines with bearing and dimensions to the nearest 1/100 of a foot.
    (c) 
    Building setback lines with dimensions.
    (4) 
    Special parcels:
    (a) 
    Description of proposed use, including a note where an offer of dedication is being made.
    (b) 
    Boundary lines with bearing and dimensions to the nearest 1/100 of a foot.
    E. 
    Water supply system:
    (1) 
    Water main location and pipe size.
    (2) 
    Fire hydrants or fire wells located as approved by the Fire Commissioners of the fire district having jurisdiction.
    (3) 
    Location of well sites, if any, on the subdivision or within 200 feet of its boundaries.
    F. 
    Sanitary waste disposal system approved by the Suffolk County Health Department:
    (1) 
    Typical lot layout indicating location of system with reference to house and water supply.
    (2) 
    Detail drawing of proposed sanitary waste disposal unit.
    (3) 
    Where municipal sewers are available, only laterals shall be shown.
    G. 
    Survey data:
    (1) 
    Survey tie-in with true angles and distances to the nearest established street monument.
    (2) 
    Municipal, Town, county and special district boundaries referenced to the subdivision survey by true angles and distances.
    (3) 
    Radii, internal angles, points of curvature, tangent bearings and lengths of all areas.
    (4) 
    Bearings and dimensions to the nearest 1/100 of a foot.
    (5) 
    Monuments.
    (a) 
    Accurate location of all monuments.
    (b) 
    Existing monuments shall be shown with this symbol:
    (c) 
    One monument shall be located at each general change in direction of street.
    (d) 
    Two monuments shall be located at each street intersection.
    (6) 
    Area of the subdivision in acres.
    (7) 
    Schedule of lot areas to the nearest square foot.
    H. 
    Signed statements:
    (1) 
    "The land shown on this map as roads, streets, or highways, or for the widening thereof, and also easements, recharge basins, park areas and all other land indicated as dedicated for other public use is hereby irrevocably offered for dedication to the Town of Brookhaven. The Town of Brookhaven is in no way responsible for the maintenance of such roads, streets or highways or other public areas until the same have been accepted by the Town."
    OWNER
    (Signed)
    (2) 
    "I hereby certify that this plat was made from an actual survey completed ___________; that all monuments have been set as shown; and that the ______________ lots on this plat are all in conformance with the requirements of Zone ___________."
    (Signed)